Description
Japanese Mitsubishi Dual Wavelength 650nm 980nm Lipo Laser Machine For Sale
Dual Wavelength 650nm 980nm Lipo Laser Machine highest energy 650 nm ~ 980 nm
Japanese “Mitsubishi” laser tube
208 diode lipolaser 12 probes 8 big 4 small
Theory of Lipolaser
The main role of the low-energy laser bio-stimulation (Bio stimulation), that is, through the give appropriate energy to stimulate the biological
cells and induce or strengthen a number of physiological responses, including to promote local blood
circulation, regulate cell function, enhance immune function, promote cell metabolism and proliferation.
Wavelength of 650nm-660nm red laser just in human eye color of the visible spectrum, so we can see the red light 650nm –
660nm can penetrate the organization up to 8-10mm, the effective activation and repair cells, stimulate the synthesis of cell metabolism, for the
superficial cells biochemical stimulation and hyperemia. Irradiation meridian points to stimulate the
meridian points related organizations, the skin tissue will not cause harm to exempt patients fear of
needles, and also have the function to stimulate the meridians in a healthy way.
Parts Introduction
Recommend treatment time and schedule:
Treated Body Area |
Recommended Treatment Time |
Recommended Treatment Schedule |
Stomach, Thigh |
20–30 minutes |
8-12 sessions,2 per week for 4-6 weeks, each session should be followed by at least 30 minutes of cardio vascular exercise within 24 hours |
Arms, Back, Buttocks, Male Breast |
15–20 minutes |
8-10 sessions,2 per week for 4-5 weeks, each session should be followed by at least 30 minutes of cardio vascular exercise within 24 hours |
Calves |
15–20 minutes |
6-8 sessions,2 per week for 3-4 weeks, each session should be followed by at least 30 minutes of cardio vascular exercise within 24 hours |
Cheeks, Chin, Neck |
10-15 minutes |
6-8 sessions,2 per week for 3-4 weeks, each session should be followed by at least 30 minutes of cardio vascular exercise within 24 hours |
Operation Process
1) Check the thickness of the fat.
2) Clean treatment area; Clear the hair of the treatment area.
3) Mark the size of treatment area.
4) The Lipolaser treatment, using the belt to fixed the pads on the treatment parts of body. wearing goggles and glasses.
Parameter
Main Power output | 220v/110v; 50Hz-60Hz |
Safety | On Board Diagnostics |
Classification | Electrical Class II, Type B applied part |
Pads | 12 pcs,8 big pads and 4 small pads |
Laser type | low intensity diode laser |
Laser source | Mitsubishi diode laser ML101J27 |
Wave length | dual wavelength, 650nm and 980nm |
Each lamp energy | 130mW~350mW (pulse) |
Quantities of lamps | 208 pcs |
Laser working mode | Continue and pulse |
Ingress Rating | IPXO |
Environmental requirement | 10°C to 40°C Non-condensing
Humidities Below 75%RH |
Cooling requirements | Air cooled |
Gross Weight | 23KGS |
CE | CE WITH LVD AND EMC |
Touch screen | 8′ TFT touch screen |
Packing size | 50CM*41CM*53CM |